Scope of application: | Suitable for anti-static places such as electronics, communication, printing, computer rooms, precision machinery, powder chemistry, military engineering, aerospace, etc |
Coating characteristics: | Having all the excellent properties of epoxy mortar flooring |
Can quickly leak static charges |
Long lasting anti-static effect |
Not affected by time, temperature, and humidity |
TECHNICAL INDEX | Drying time - surface drying: ≤ 4H |
Drying time - practical: ≤ 24 hours |
Pencil hardness: ≥ 2H |
Impact resistance (500g steel ball): through g.cm |
Wear resistance (750g/500r): ≤ 0.03g |
Compressive strength: ≤ Grade 1 |
Surface Resistivity | Middle coating | 1.0 × 10 ^ 4 ^ -1.0 × 10 ^ 5 ^ |
TOP COAT | 2.5 × 10 ^ 4 ^ -1.0 × 10 ^ 9 ^ |
Volume resistivity | 1.0 × 10 ^ 4 ^ -1.0 × 10 ^ 9 ^ |
|
Construction procedures | construction method | Main materials - auxiliary materials | Reference amount |
Plain ground | Do a good job in waterproofing treatment |
|
|
undercoat | Scrape and apply epoxy primer | DS-30# | About 0.15kg/m ² |
screed | Scrape quartz sand with epoxy coating | DS-400- Quartz sand | 0.25-0.7kg/m²
|
Putty layer | Apply a scraping putty layer with epoxy coating | DS-400 | 0.1kg/m2 once |
Laying copper foil | Lay copper foil horizontally and vertically at intervals of 1.5-2m (seal the copper foil with Dongsheng DS-401 once) | DS-900 | 0.25-3.0kg/m² |
Conductive intermediate coating | Scrape and roll the conductive carbon black coating once | DS-401 | 0.12kg/m2 once |
top coat | Roll coating anti-static flat topcoat | DS-700 | 0.15---0.18kg/m2 |
|
Construction procedures | Coating thickness: generally 1mm-3mm. If it exceeds 2mm, it needs to be sandblasted |
Personnel can only enter after 24 hours of construction completion, and heavy pressure can only be applied after 72 hours. (Based on 25 * C, the low-temperature opening time needs to be moderately extended) |